Laboratory and antibacterial HPL panels
Laboratory and antibacterial HPL panels for clinics, schools, research institutes and production. The non-porous surface doesn’t absorb moisture or dirt; antibacterial activity is confirmed by tests to JIS Z 2801, and resistance to your reagents by a test report on request.
Four products — one laboratory and antibacterial material
Two systems — fixings out of sight
The system depends on the panel thickness: 4–6 mm — glued to a profile, from 8 mm — a hanging system on a profile (per the material’s technical data sheet).
Adhesive system
For panels 4–6 mm. The profile is fixed to the wall, adhesive sealant is applied to it in strips, and the panel is pressed on. The face stays intact — no holes or fixings.
- Profile on the wall
- Adhesive sealant
- The panel is pressed on
Concealed system
For panels from 8 mm. The back of the panel has hooks, and the wall has a profile with matching elements. The panel is hung and drops into place; no fixings are visible from the front.
- Hook profile
- The panel is hung
- Drops down into place
A surface that doesn’t absorb dirt
49 reagents — test passed
SGS tests to SEFA 3-2020 for laboratory surfaces: 24 hours of contact at 23 °C. 35 reagents — no change (level 0), 14 — a slight change in colour or gloss without affecting properties (level 1), no unacceptable changes — result PASS.
Level for each reagent
SGS report dated 04.09.2024: laboratory compact, black surface, 12.7 mm. The results apply to the tested sample. 0 — no change; 1 — a slight change in colour or gloss; properties and service life are unchanged. Before ordering, we will check your list of reagents with a technologist. Data sheet and test reports at the end of the page ↓
More than 99.99% of bacteria — in 24 hours
Independent SGS tests to the Japanese standard JIS Z 2801: four types of bacteria were applied to the HPL surface and compared with a control sample after 24 hours. A surface is considered antibacterial at an activity of R ≥ 2 — for the tested HPL it was 4.2 to 6.16.
- Staphylococcus aureusStaphylococcus aureus> 99,99 %fewer bacteria after 24 hoursR > 4,2 against a requirement of R ≥ 2
- Escherichia coliEscherichia coli> 99,9999 %fewer bacteria after 24 hoursR > 6,16 against a requirement of R ≥ 2
- KlebsiellaKlebsiella pneumoniae> 99,999 %fewer bacteria after 24 hoursR > 5,82 against a requirement of R ≥ 2
- SalmonellaSalmonella> 99,998 %fewer bacteria after 24 hoursR > 4,98 against a requirement of R ≥ 2
Antibacterial cladding: HPL on ACP
A 4 mm aluminium composite panel (ACP) is fixed with self-tapping screws directly to the wall or plasterboard — no frame. HPL of 3, 4, 6 or 8 mm is bonded to it with the SikaTack® adhesive system, and 5 mm joints are filled with sanitary sealant — a wall with no open joints that is easy to clean. Material consumption per 1 m² is in the calculator.
- Preparing ACP and HPL
Cleaning surfaces with Sika® Cleaner P where the technology specifies it for particular coatings.
- Surface activation
Treatment with Sika® Aktivator-205 according to the manufacturer’s instructions.
- Applying primer
SikaTack® Panel Primer on the surfaces the system specifies it for.
- Applying the tape
SikaTack® Panel Fixing Tape.
- Bonding HPL
Applying SikaTack® Panel-50 and installing the panel.
- Sealing
Filling 5 mm joints between panels with sanitary sealant after the joints are prepared.
Seven layers of the wall — interior and laboratory
From substrate to surface: an ACP base, the Sika adhesive system, the panel and a sanitary joint — no frame. Quantities per UZHPL calculation.
The diagram is an illustration. The system, thickness and fixings are determined by the room and the design; quantities per UZHPL calculation.
For which projects
Prices and thicknesses by HPL type
Laboratory HPL decors
Colours are not shown accurately on screen. Some decors can be seen in person at the showroom on 235 Parkent St.
Questions about laboratory and antibacterial panels
Didn’t find an answer? Message us on Telegram or call — an engineer will reply within one working day.
How chemically resistant is the surface?
To SEFA 3-2020 (SGS report, 2024): of 49 reagents, 35 left no change, 14 caused a slight change in colour or gloss without affecting properties, and there were no unacceptable changes — the test was passed. A laboratory compact with a black surface was tested; before ordering we will check the list against your reagents.
What thickness are the worktops?
Laboratory HPL 16 and 20 mm is for worktops and sinks. Wall panels come in the same thicknesses as interior panels; an engineer will choose the exact thickness for the room.
How are wall panels fixed?
Two systems with invisible fixings: adhesive for 4–6 mm panels, concealed on hooks from 8 mm.
Where can I get the technical data sheet and test reports?
The technical data sheet is open in the technical library, test reports on request.
Is there an antibacterial effect?
Yes. According to SGS tests to JIS Z 2801, after 24 hours the number of bacteria on the HPL surface is reduced by more than 99.99% (Staphylococcus aureus, E. coli, Klebsiella, Salmonella; activity R from 4.2 to 6.16 against a requirement of R ≥ 2). The report is available on request; the manager will confirm applicability to the series and decor. More ↑
Is it suitable for clinics and schools?
Yes. The surface is non-porous: it doesn’t absorb moisture or dirt and withstands daily wet cleaning with household chemicals.
How do I calculate the cost?
In the calculator walls and laboratory furniture are calculated separately; an engineer will prepare the exact estimate, usually within 24 hours.